Namino

MP1200 P6

4 digit display in a 48x96 box for 4÷20mA, 0÷20mA, 0÷10V input and thermocouples J, K, S, and Pt100. Optional 3 relay alarm outputs, analogue output and serial outputs.

The MP1200 P6 model is an instrument with a dual slope converter to interface transducers (2 or 3 wires), thermocouplings and thermoresistors or voltmeter/ammeter amplifiers.

The scales available are listed in the "Features" section.

The instrument has the following functions:

  • 4 digit indicator (-1999÷9999)
  • reading of any input value inside the requested range
  • zeroing of automatic reading function
  • reading at 4 conv/sec (no programmed filter)
  • fixed zero (visualization from -1990 to 9990)
  • possibility of read out with 20 steps linearization

The MP1200 P6 instruments can be ordered with the following options:

  • 2 relay alarm outputs (three if 220V power supply) programmable for value, hysteresis and delay
  • analogue outputs (4÷20mA or 0÷20mA or 0÷10V)
  • RS232, RS422 or RS485 serial output

Readings: 4 digits
Accuracy better than: 0,5%
Thermal stability: 50 ppm/°C
Transducer power supply* : 16V/20mA (unregulated)
Inputs: TC: J, K, S; RTD PT100; 0÷20mA; 4÷20mA; 0÷10V
Analogue outputs features:

  • Outputs: 4÷20mA - 0÷20mA - 0÷10V
  • Max load for current output: 400Ω
  • Min. load for voltage output: 1KΩ
  • Resolution: 12 bit

Exchange relay output: 5A / 250Vac
Power supply: 90÷260 Vac/Vdc, 25Vac, Vcc o Vpt (12[divid]30Vdc)
Power absorption: 1,5 W
Max working temperature: 50 °C
Digits height: 13mm
Dimensions: 48x96 (75 mm. Depth)
Mounting plate: 44.5mm (h) x 92.5 mm (l)
Weight: 250 gr.
Mounting: by bolts

* with dc power supply, Val=14Vdc if Vdc power supply >16Vdc

OPTIONS AND SERIAL OUTPUTS

SR2: 2 relay alarms
SR3: 3 relay alarms (only with 220V power supply)
OAP: analogue outputs

Cod. 2: RS 422 bi-directional
Cod. 3: RS 485 bi-directional
Cod. 4: RS 232 bi-directional

MEASURING SCALES

INPUTMEASURING SCALESIMPEDANCE
0 ÷ 10 V-1999 ÷ 99991MΩ
0 ÷ 20 mA-1999 ÷ 999920 Ω
4 ÷ 20 mA-1999 ÷ 999920 Ω
Fe/CO0÷600 °C
Ni/Cr-Ni0÷1200 °C
Pt/Pt-Rh10%0÷1710 °C
PT100 e-40÷800 °C
PT100 r-40.0÷410.0 °C
termoregolatore
MP20 M1

4-digit Display (A, V) in 48x48.

visualizzatore
MP30 P2

4 digit display with fixed scale in a 36x72 box

visualizzatore
MP40 P6

4 digit display (A, V) in a 48x96 box.

display
MP45 P6

4 digit display (A, V) with two alarms in a 48x96 box.

visualizzatori
MPA-MPV-MPP P6

4-digit Display (A, V) in 48x96; 2 alarm relay; Analog output.

display
MPA - MPV M6

4½ digit display in a 48x96 box for AC or DC current or voltage input (A,V).

visualizzatori
MPM P6

4-digit Display (A, V) in 48x96; 2/3 alarm relay; Analog and serial outputs.

display
MPPV010 P6

OUT OF PRODUCTION - 5-digit Display for load cell in 48x96; 2/3 alarm relay; Analog and serial outputs.

visualizzatori
MPPV340 M6

4½ digit display in a 48x96 box for strain gauge (load cell) input.

display
MPP323 M6

4½ digit display in a 48x96 box for potentiometer transducer.

display
MPO347 M6

4½ digit display in a 48x96 box for Ohm measures (ohmmeter).

visualizzatori
MP2200 M6

4½ digit display in a 48 x 96 box for 4-20mA, 0-20mA, 0-10V. Input ant thermocouples J, K, and Pt100.

This site uses third-party services that install profiling cookies. You can accept cookies or visit the site with reduced functionality. If you want to learn more or opt out of all or some cookies, see the extended information.
Extended information